Call Us At: 1 (866) 957-9993Call Us At: 1 (866) 957-9993
Manifold Plates

Manifold plates from STEINEL are suitable for high-density tools with high force requirements in a small space.

They consist of multiple nitrogen cylinders and a control panel, which are connected to one another via boreholes in the lower plate. As with tube composite systems, this ensures uniform system pressure and a larger nitrogen volume, resulting in a flatter force curve. Composite plates from STEINEL are particularly compact and reliable.

Cylinder 5500 daN ST 8841-1-055, ST 8841-2-055, ST 8841-3-055

Description

Order No. ST 8841-1-055 Order No. ST 8841-2-055 Order No. ST 8841-3-055
DesignationStroke mmGH T TP H GP GH T TP H GP GH T TP H GP
006 6.0 14.0 39.5 42.5 22.0 23.0
010 10.0 14.0 43.5 46.5 26.0 23.0
015 15.0 14.0 48.5 51.5 31.0 23.0
020 20.0 14.0 53.5 56.5 36.0 23.0
025 25.0 61.5 25.0 28.0 88.5 23.0 52.5 34.0 37.0 79.5 23.0 14.0 58.5 61.5 41.0 23.0
038 38.0 86.5 25.0 28.0 114.5 23.0 52.5 47.0 50.0 92.5 23.0
050 50.0 86.5 25.0 28.0 138.5 23.0 52.5 59.0 62.0 104.5 23.0
075 75.0 111.5 25.0 28.0 188.5 23.0 52.5 84.0 87.0 129.5 23.0
100 100.0 136.5 25.0 28.0 238.5 23.0 52.5 109.0 112.0 154.5 23.0
150 150.0 186.5 25.0 28.0 338.5 23.0 52.5 159.0 162.0 204.5 23.0

Order example 1: Manifold cylinder variant 3 (5500 daN) with a stroke of 6 mm Order number: ST 8841-3-055 x 006

Further dimensions/details:

  • Housing outer diameter = 108 mm
  • Piston rod outer diameter = 40 mm
  • Screw-in thread = M100 x 2
  • Minimum bore Ø under M100 x 2 = 97 mm
  • d = 12 mm
  • Pmin (Steel) = 13 mm Pmin (Aluminium) = 15 mm
  • Piston active surface Azyl = 50.24 cm²
  • Minimum filling pressure = 40 bar
  • Maximum filling pressure = 150 bar

Key:

  • d = Minimum connecting hole diameter
  • D1 = Minimum bore Ø
  • G = Thread length housing
  • GH = Case height
  • GP = Minimum depth of thread cylinder mounting hole
  • H = Overall height, piston extended
  • Hub = Maximum usable stroke
  • KD = Piston rod outer diameter
  • Pmin = Minimum distance to the next interfering contour
  • T = Installation depth housing
  • TP = Minimum borehole depth cylinder mounting hole
  • Filling pressure-depending initial forces

    The end forces are a maximum of 20% higher, depending on the pressure increase and/or the available volume.

    a) Required filling pressure:

    The required filling pressure is calculated as follows: Filling pressure = requested force ÷ piston active surface e.g. 5000 daN ÷ 50.24 cm² = 99.522293 bar ~ 99,5 bar These examples are based on one cylinder each of the type ST 8841-1-055, ST 8841-2-055 or ST 8841-3-055

    b) Calculating initial force:

    The initial force is calculated by multiplying the piston active surface (50.24 cm²) with the filling pressure. Initial force = piston active surface x filling pressure e.g. 50.24 cm² x 120 bar = 6028.8 daN

    Order example 2: Manifold cylinder variant 1 (5500 daN) with a stroke of 100 mm Order number: ST 8841-1-055 x 100

    Share this product

    About Champion Tools

    Delivering high precision die components to our customers in North America and South America.